Exide Inverterz Magic

Exide Inverterz - LKVA HOME UPS SIZING

Exide LKVA Home UPS can be customized to suit your need and budget. Key in the specifics and pick the right Home UPS from the Exide Inverterz range.

Click Here

Features

  • DSP (Digital Signal Processor) based design for more reliability with SMT technology*
  • Pure Sine Wave output wave form same as Mains/Grid Power
  • ASIC (Auto Sense Intelligent Control) technology for battery charging, automatically senses battery conditions & adjusts the charging current accordingly
  • Programmed inbuilt ventilation fan which operates as needed
  • Extremely Low Harmonics
  • Tri Colour of LCD display for better user interface*
  • Dual State of Charging
  • Auto smart protection built-up in PCB, such as Short Circuit, Overload, Battery Over-Charge, Battery Low, Heat-up, AC Fuse Trip, Phase Reverse, etc.
  • Battery Charging Range in Normal Mode i.e. 100V ~ 280V
  • Battery Charging Range in UPS Mode i.e. 180V ~ 260V
  • Change Over Time Mains to UPS and vice versa < 10msec
  • Noiseless Operation

Technical Specifications of Exide Inverterz Magic

Description MAGIC 12V 700VA MAGIC12V 825VA MAGIC12V 1050VA MAGIC 24V 1500VA
Output Voltage at No Load 235V ± 15V AC
Output Frequency 50Hz ± 1Hz
Output Wave Form Square Wave
Nominal Battery Voltage 12V DC 24V DC
Battery Low Cut Off 10.5V ± 0.2V DC 21.0V ± 0.4V DC

Charging Mode

Model MAGIC 12V 700VA MAGIC12V 825VA MAGIC12V 1050VA MAGIC 24V 1500VA
Maximum Charging Current (NC) 09.5Amp ± 1.5Amp 10Amp ± 1.5Amp 17Amp ± 1.5Amp 17Amp ± 1.5Amp
Maximum Charging Current (HC) 13Amp ± 1.5Amp 14Amp ± 1.5Amp 12.5Amp ± 1.5Amp 12.5Amp ± 1.5Amp
Boost Charging Voltage 14.4V ± 0.2V DC 28.8V ± 0.4V DC
Trickle Charging Voltage 13.7V ± 0.2V DC 27.4V ± 0.4V DC
Charging Current at 120V Mains Input 8-10 Amp Charging Current*
Changeover Time Mains to Back-up (@ UPS Mode) ≤ 10 msec
Changeover Time Back-up to Mains (@ UPS Mode) ≤ 10 msec
Changeover Time Mains to Back-up (@ Normal Mode) ≤ 40 msec
Changeover Time Back-up to Mains (@ Normal Mode) ≤ 10 msec
Input Voltage Range (@ Normal Mode) 100V - 290V AC

*Depends upon Battery Voltage